SETTE configurations with ice model component fail when ice outputs are activated
Context
I get a floating point exception when trying to run tests with ice model activated. The exception happens in the xios library during output.
If I disable ice model outputs (by commenting an include in context_nemo.xml
: <file_definition src="./file_def_nemo-ice.xml"/>
) the test passes.
I am attaching job and ocean_ouput logs:
I was wondering if you have already seen this problem before?
Please provide informations on how to reproduce the bug:
-
Branches impacted: tag 4.2.2 -
Reference configuration/test cd sette; ./sette.sh -n ORCA2_ICE_PISCES
-
Computing architecture: intel one 2021.4 compiler and MPI, parallel netcdf netCDF-Fortran 4.4.5
-
Dependencies: XIOS (trunk of XIOS2: r2590), ... -